EPA 608 Plan

Core plus a type, 70 percent to pass, and a credential that never expires. Straight from the regulation.

For HVAC and refrigeration technicians certifying under section 608 of the Clean Air Act who want the exam structure, the evacuation and leak-rate numbers, and the certification-type decision traced to the Code of Federal Regulations rather than to a prep vendor.

What this site is

EPA 608 Plan is an independent EPA 608 preparation resource built from the United States Environmental Protection Agency's published blueprint (40 CFR part 82 subpart F, appendix D, section d). Every fact page cites its primary source and shows the date it was last verified. The free diagnostic weights questions like the real exam, then turns your results into a study plan you can regenerate as you improve.

Exam blueprint: 4 content areas

Weights from the United States Environmental Protection Agency; verified 2026-09-22.

Core25%

Core is 25 of the items on whichever Section 608 test you sit, and 25 of the 100 on Universal. Appendix D fixes its three areas: the environmental impact of CFCs, HCFCs and substitute refrigerants; laws and regulations; and the changing industry outlook. EPA's own topic list adds refrigerant identification, the three R definitions, recovery technique, dehydration evacuation, safety and cylinder handling, and shipping labels.

Type I — small appliances25%

Type I certifies you to maintain, service or repair small appliances — units manufactured, charged and hermetically sealed in a factory with five pounds of refrigerant or less. Its 25 items concentrate on recovery: the 80 and 90 percent thresholds, the four inches of mercury alternative, passive recovery from a unit whose compressor has failed, and access valves. It is the only type that may be offered as a mail-in test.

Type II — medium, high and very high-pressure appliances25%

Type II certifies work on medium-, high- and very high-pressure appliances other than small appliances, MVACs and MVAC-like appliances. Its 25 items are the densest on the exam: the Table 1 evacuation levels, which change with charge size and with whether the recovery machine predates 15 November 1993, the leak rate thresholds, major versus non-major repairs, and the prohibition on system-dependent equipment above 15 pounds.

Type III — low-pressure appliances25%

Type III certifies work on low-pressure appliances — those using a refrigerant with a liquid-phase saturation pressure below 45 psia at 104 °F, such as R-11, R-123 and R-245fa. Low-pressure centrifugal chillers run under a vacuum, which inverts most of what Type II teaches: leaks draw air and moisture in rather than pushing refrigerant out, recovery is to 25 mm Hg absolute, and pressurising for a leak test is done with controlled heat first, with nitrogen only as the fallback.

Free tools

Exam facts, sourced

Where do you actually stand on the EPA 608?

20 original questions, weighted like the real blueprint. No signup. Results in minutes.

Take the free diagnostic

Latest updates

Free question bank: 20 original questions (20 editor-approved). Questions are written by our team against the published blueprint and never copied from any exam.